Healthcare Professional Verification

This section contains medical information for licensed healthcare professionals only. Please confirm your professional status to continue.

HYDRASHIFT

Avoid interferences due to therapeutic Monoclonal Antibody with HYDRASHIFT Portfolio.

About HYDRASHIFT

Therapeutic monoclonal antibody (mAb) inclusion in Multiple Myeloma treatment regimens offer patients significant improvements in clinical outcomes. daratumumab and isatuximab are human mAb targeting CD38 used in Multiple Myeloma treatment regimens.

HYDRASHIFT avoids therapeutic mAb interference on Immunofixation interpretation assays.

Sebia HYDRASHIFT Gel, provided by the HYDRASYS 2 SCAN FOCUSING instrument

Pathologies associées

Technologies utilisées

Key Benefits

HYDRASHIFT : A simple and reliable solution to eliminate interferences from therapeutic monoclonal antibodies.
  • Distinctive shift technology

    HYDRASHIFT daratumumab and HYDRASHIFT isatuximab avoid daratumumab or isatuximab interference on HYDRAGEL IF tests.

  • Trust in the results

    HYDRASHIFT reduce the risk of incorrect IF interpretation to improve therapy monitoring.

  • Easy to implement

    Fully integrated into IF protocol without sample pre-treatment for a standardized process compliant to IMWG guidelines.

  • Follow IMWG guidelines

    Process compliant to IMWG guidelines to assess response to treatment in patient with Multiple Myeloma.

Main characteristics

Test principle

HYDRASHIFT is an immunofixation technique performed on HYDRAGEL IF 2/4 gel that works by creating immune complexes between therapeutic monoclonal antibodies (daratumumab or isatuximab) and specific anti-mAB antisera. The resulting complexes shift migration to the alpha region, facilitating distinction from patient M-proteins.

This complex is visible in the IgG and kappa immunofixation tracks. A negative HYDRASHIFT result demonstrates the absence of endogenous M-protein.

Sample type

Serum

Performances

Sensitivity

The limit of immune complex visualized is 30 mg/dL.

Product details

  • HYDRASHIFT 2/4 daratumumab (20 tests) – P/N: 4639
  • daratumumab control – P/N: 4765
  • HYDRASHIFT 2/4 isatuximab (40 tests) – P/N: 4642
  • isatuximab control P/N: 4764

Knowledge & Science

No content available.

HYDRASHIFT test can be performed on the following instrument

No content available.

Tests related to HYDRASHIFT

Cette section contient des informations destinées à une large diffusion et peut donc comporter des détails sur des produits ou des informations qui ne sont pas disponibles ou valables dans votre pays. Veuillez contacter votre représentant Sebia local. Informations destinées aux professionnels de santé. Lisez attentivement les instructions figurant dans les notices des réactifs et les manuels d'utilisation des instruments.