Effects of hemoglobin C, D, E and S traits on measurements of hemoglobin A1c by twelve methods

Hemoglobin C, D Punjab, E or S trait can interfere with hemoglobin A1c (HbA1c) results depending on the method of analysis used. Therefore, it is important to know the limitations of the method used for HbA1c determination.

Publié: 12/11/2026 | Modifié: 12/11/2026

Hemoglobin A1c (HbA1c) is widely used for diabetes monitoring and diagnosis. As HbA1c results play a key role in clinical decision-making, analytical accuracy is essential to ensure appropriate patient management.

Hemoglobin variants can interfere with HbA1c measurements obtained with some assay methods. Common variants such as Hb S, Hb C, Hb E and Hb D-Punjab may lead to falsely elevated or falsely decreased HbA1c results. Clinically significant interference can result in inappropriate treatment decisions, including over-treatment with an increased risk of hypoglycemia or under-treatment associated with prolonged hyperglycemia and diabetes-related complications. In addition, inaccurate HbA1c results may impact the diagnosis of diabetes.

Hemoglobin variants are not uncommon and may be encountered in routine laboratory practice, particularly in regions with ethnically diverse populations. It is therefore important for laboratories to understand the susceptibility of HbA1c methods to variant interference and to select methods that have been demonstrated to provide accurate results in the presence of common hemoglobin variants. In this study, several methods, including capillary electrophoresis (CE) systems, showed no clinically significant interference from Hb S, Hb C, Hb E or Hb D-Punjab traits.

HbA1c-2_Publication

Test associated with this resource

Related instruments

  • Le concentré du savoir-faire de Sebia dans un instrument à haute cadence analytique.

    CAPILLARYS 3 TERA
  • Solution d’électrophorèse capillaire pour répondre à vos besoins en matière de haute capacité.

    CAPILLARYS 3 TERA MC

Discover more resources on Diabetes

Cette section contient des informations destinées à une large diffusion et peut donc comporter des détails sur des produits ou des informations qui ne sont pas disponibles ou valables dans votre pays. Veuillez contacter votre représentant Sebia local. Informations destinées aux professionnels de santé. Lisez attentivement les instructions figurant dans les notices des réactifs et les manuels d'utilisation des instruments.